2365-L3 625

2365-L3 625

Professional Development

11 Qs

quiz-placeholder

Similar activities

AIMRA

AIMRA

Professional Development

10 Qs

PowerPoint IMiL Quiz

PowerPoint IMiL Quiz

Professional Development

13 Qs

NTDP - BUILDING PARTNERSHIP

NTDP - BUILDING PARTNERSHIP

Professional Development

15 Qs

Gk Marathon-11 Quiz

Gk Marathon-11 Quiz

10th Grade - Professional Development

15 Qs

Governing Circular

Governing Circular

Professional Development

14 Qs

RBE Quiz

RBE Quiz

Professional Development

12 Qs

gents dry and finish

gents dry and finish

Professional Development

12 Qs

Virtual Privilege Walk

Virtual Privilege Walk

Professional Development

15 Qs

2365-L3 625

2365-L3 625

Assessment

Quiz

Other

Professional Development

Easy

Created by

kevin barnett

Used 6+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

identify the type of emergency light fitting the remains lit continuously
sustained
contained
maintained
non maintained

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

identify the rating of an RCD used for additional protection for buried cables in walls.
100mA
20mA
13A
30mA

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

when applying DIVERSITY to discharge lighting (such as fluorescent lamps), identify the multiplication factor that should be applied to the lamp wattage
2
1.8
10
5.5

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

identify the rated short-circuit capacity of a BS88-6 device at 240v, as detailed in the On Site guide
16kA
33kA
16.5kA
31.5kA

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

how can long runs of pvc conduit be installed to reduce the prospect of distorting and buckling due to large changes in ambient temperature.
greater distances between saddles
pvc conduit must not be installed in these environments
regular through-boxes are used throughout the run
use expansion couplers

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

identify the maximum 'measured' Zs value allowed for a type B 16A circuit breaker to BSEN60898, as detailed in the On Site guide
3.5 ohms
1.09 ohms
2.2 ohms
1.58 ohms

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

if an overcurrent occurs in an otherwise healthy circuit, this would be called ........
an open circuit
an earth fault
a short circuit
an overload

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?