L3 Electrical - Earthing, Safety & Testing

L3 Electrical - Earthing, Safety & Testing

Assessment

Quiz

Other

1st - 3rd Grade

Practice Problem

Hard

Created by

Rober Kerr

Used 61+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical intake system which uses an earth rod would be classed as

TT

TN-S

TN-C-S

PME

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical intake system whereby the main earth conductor is connected to the sheath of the incoming supply cable is known as

TT

TN-S

TN-C-S

NC-S

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The earthing system whereby the neutral combines the function of both neutral and earth is termed

TN-S

TT-S

TN-C-S

NE-S

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The size of the main earthing conductor would typically be

6mm2

10mm2

12mm2

16mm2

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The size of the main bonding conductor would typically be

4mm2

6mm2

10mm2

16mm2

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following tests should be carried out on the earthing circuit with the circuit live?

Earth Loop Impedance

Insulation Resistance

Earth Continuity

Polarity Test

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A test current of 150mA should cause a 30mA RCD to trip out in which of the times listed below?

0.4 seconds

40 milliseconds

4 seconds

4 milliseconds

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?