Training Quiz AU480 A

Training Quiz AU480 A

Professional Development

31 Qs

quiz-placeholder

Similar activities

TECVİD 2 ( Medlerin Kuvvet Dereceleri )

TECVİD 2 ( Medlerin Kuvvet Dereceleri )

Professional Development

35 Qs

Organizational Behavior

Organizational Behavior

Professional Development

26 Qs

Examen Python

Examen Python

Professional Development

26 Qs

PC 1 3CT

PC 1 3CT

Professional Development

26 Qs

Introducing Windows 11

Introducing Windows 11

KG - Professional Development

26 Qs

The Bay - Level 1 Assessment Exam

The Bay - Level 1 Assessment Exam

Professional Development

35 Qs

UT 1 UNIDAD DE PACIENTE

UT 1 UNIDAD DE PACIENTE

Professional Development

27 Qs

Medical Abbreviations

Medical Abbreviations

Professional Development

35 Qs

Training Quiz AU480 A

Training Quiz AU480 A

Assessment

Quiz

Professional Development

Professional Development

Practice Problem

Easy

Created by

Saf fone

Used 177+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

31 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

What is the throughput for Beckman Coulter AU480 Chemistry Analyzer (photometric + ISE optical)?

400

600

800

900

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many type of rack applicable in AU Chemistry analyzer series?

5

4

7

6

3.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

Media Image

How many sample position in STAT Table?

18

22

24

25

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

How to check Calibration Factor LIst without using the shortcut button or user menu?

Menu > Calibration > Calibration Monitor > Status > Factor List

Men > Calibration > Calibration Detail > Status > Factor List

Menu > Calibration > Calibration History > Status > Factor List

Menu > Calibration Monitor > Calibration Detail > Factor List

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

How to check a daily Quality Control without using shortcut or user menu?

Menu > QC > QC Monitor > Daily Control

Menu > QC > QC Monitor > Day to day Control

Parameter > QC Monitor > Daily Control

Parameter > QC Monitor > Day to day Control

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

Which of the following stability period for he ISE reagent once open?

ISE Reference - 2 months / ISE Buffer - 1 Month / ISE Mid Standard - 2 Months

ISE Reference - 2 months / ISE Buffer - 2 Months / ISE Mid Standard - 1 Month

ISE Reference - 3 months / ISE Buffer - 2 Montha / ISE Mid Standard - 1 Month

ISE Reference - 1 month / ISE Buffer - 2 Months / ISE Mid Standard - 1 Month

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

These condition required for re-calibrate except

Change of detergent

Change Calibrator

The QC is outside SD limit

Change reagent

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?