Training Quiz AU480 A

Training Quiz AU480 A

Professional Development

31 Qs

quiz-placeholder

Similar activities

D47 FACE THE CHALLENGE

D47 FACE THE CHALLENGE

Professional Development

30 Qs

Quiz 3 - ITEDEV - Final

Quiz 3 - ITEDEV - Final

Professional Development

30 Qs

FC_LEVEL IV_UNIT 11_MUSIC/DETERMINERS

FC_LEVEL IV_UNIT 11_MUSIC/DETERMINERS

Professional Development

28 Qs

ARMIS Home Support Training Recap

ARMIS Home Support Training Recap

Professional Development

27 Qs

Odoo 15 Cert - Human Resource - Quiz

Odoo 15 Cert - Human Resource - Quiz

Professional Development

30 Qs

QEHS Geeks

QEHS Geeks

Professional Development

30 Qs

DPIN-00

DPIN-00

Professional Development

30 Qs

Salesforce 101 Assessment

Salesforce 101 Assessment

Professional Development

30 Qs

Training Quiz AU480 A

Training Quiz AU480 A

Assessment

Quiz

Professional Development

Professional Development

Easy

Created by

Saf fone

Used 177+ times

FREE Resource

31 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

What is the throughput for Beckman Coulter AU480 Chemistry Analyzer (photometric + ISE optical)?

400

600

800

900

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many type of rack applicable in AU Chemistry analyzer series?

5

4

7

6

3.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

Media Image

How many sample position in STAT Table?

18

22

24

25

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

How to check Calibration Factor LIst without using the shortcut button or user menu?

Menu > Calibration > Calibration Monitor > Status > Factor List

Men > Calibration > Calibration Detail > Status > Factor List

Menu > Calibration > Calibration History > Status > Factor List

Menu > Calibration Monitor > Calibration Detail > Factor List

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

How to check a daily Quality Control without using shortcut or user menu?

Menu > QC > QC Monitor > Daily Control

Menu > QC > QC Monitor > Day to day Control

Parameter > QC Monitor > Daily Control

Parameter > QC Monitor > Day to day Control

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

Which of the following stability period for he ISE reagent once open?

ISE Reference - 2 months / ISE Buffer - 1 Month / ISE Mid Standard - 2 Months

ISE Reference - 2 months / ISE Buffer - 2 Months / ISE Mid Standard - 1 Month

ISE Reference - 3 months / ISE Buffer - 2 Montha / ISE Mid Standard - 1 Month

ISE Reference - 1 month / ISE Buffer - 2 Months / ISE Mid Standard - 1 Month

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

These condition required for re-calibrate except

Change of detergent

Change Calibrator

The QC is outside SD limit

Change reagent