Electrical Testing and Inspection 2

Electrical Testing and Inspection 2

University

20 Qs

quiz-placeholder

Similar activities

Electricity Vocab Quiz

Electricity Vocab Quiz

KG - University

15 Qs

Series and Parallel Circuits Activity

Series and Parallel Circuits Activity

KG - University

20 Qs

Electric circuits

Electric circuits

University

15 Qs

Circuits Intro

Circuits Intro

4th Grade - University

20 Qs

Ridin' the Waves Pre-Test

Ridin' the Waves Pre-Test

KG - University

15 Qs

Series and Parallel Circuits Activity

Series and Parallel Circuits Activity

8th Grade - University

20 Qs

Series or Parallel

Series or Parallel

8th Grade - University

20 Qs

Electrical Fault Finding B

Electrical Fault Finding B

University

15 Qs

Electrical Testing and Inspection 2

Electrical Testing and Inspection 2

Assessment

Quiz

Physics

University

Hard

Created by

Craig Carlin

Used 245+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

Given the following numbered tests, select the sequence in which these tests should be conducted for a new installation:- 1. functional 2. insulation resistance 3. polarity 4. continuity of final ring conductors 5. continuity of protective conductors:

1,3,4,5,2

4,5,3,2,1

5,4,2,3,1

2,3,4,5,1

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Table 9A in the On Site Guide gives a value of 19.51 (mohm/m) for a line conductor of 2.5mm2 and a protective conductor of 1.5mm2. What would be the resistance of a circuit 25m in length when wired using these conductors:

4.87 ohm

487 ohm

780 ohm

0.487 ohm

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following tests would be carried out 'live':

insulation resistance

earth continuity

prospective fault current

ring circuit continuity

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An approved voltage tester can be used to:

Establish whether a circuit conductor is live or not

Determine the effectiveness of a disconnection device

Measure the resistance of an earth continuity conductor

Carry out continuity tests

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following does not form part of the earth fault loop impedance

The phase conductor

The earth electrode

The cable armouring

The neutral within the consumer's installation

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

An earth fault loop impedance tester should only allow current to flow for:

0.4s

4.0s

40ms

400ms

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A 100ma RCD protecting a TT installation tested at half the rated tripping current should

Not operate

Operate within 50ms

Operate within 100ms

Operate within 300ms