Electrical Inspection and Testing 1

Electrical Inspection and Testing 1

University

20 Qs

quiz-placeholder

Similar activities

Electrical Fault Diagnosis and Rectification

Electrical Fault Diagnosis and Rectification

University

15 Qs

Electrical Fault Finding A

Electrical Fault Finding A

University

20 Qs

Regs Exam 3

Regs Exam 3

KG - University

18 Qs

electric curcuits

electric curcuits

KG - Professional Development

15 Qs

Regs Exam 1

Regs Exam 1

KG - University

18 Qs

Transformer and Safety

Transformer and Safety

University

20 Qs

Science & Maths revision

Science & Maths revision

6th Grade - Professional Development

21 Qs

Series and Parallel

Series and Parallel

KG - University

21 Qs

Electrical Inspection and Testing 1

Electrical Inspection and Testing 1

Assessment

Quiz

Physics

University

Hard

Created by

Craig Carlin

Used 409+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

OSG gives the maximum stable value of Ze for a TT installation as:

1660 ohms

600 ohms

200 ohms

100 ohms

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which type of earthing system relies on a separately supplied earth, usually the sheathing on the cable:

TT

TN-C-S

IT

TNS

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following would not be one of the human senses to use during the initial verification of an addition to a lighting circuit:

Sight

Hearing

Taste

Touch

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

On a standard TT installation, the result of the resistance of the earth electrode and the rated RCD residual operating current should not exceed:

25v

50v

110v

400v

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following protection devices is unlikely to be suited for short circuit currents in the region of 6kA:

BS 3036 semi-enclosed fuse

BS 88-3 cartridge fuse

BS 88-2 general purpose fuse

BS EN 60898 circuit breaker

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The term given to the person responsible for an electrical system is the:

Competent person

Electrician

Duty holder

Company manager

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Regional electricity companies quote a maximum likely value of external loop impedance (outside the consumer's installation) for a TN-S system as:

0.35 ohm

0.8 ohm

21 ohm

200 ohm