NFPA 25 5.4 review quiz

NFPA 25 5.4 review quiz

University

15 Qs

quiz-placeholder

Similar activities

NFPA 25 5.2 Review quiz

NFPA 25 5.2 Review quiz

University

18 Qs

Active and Passive Voice

Active and Passive Voice

10th Grade - Professional Development

10 Qs

CCEYA

CCEYA

University

16 Qs

Final Quiz No. 3

Final Quiz No. 3

University

10 Qs

Future Continuous - Fast Thinking

Future Continuous - Fast Thinking

8th Grade - Professional Development

15 Qs

Mastery Peak of Q9 and Q10 Semi-Finals MARLAW

Mastery Peak of Q9 and Q10 Semi-Finals MARLAW

University

20 Qs

Limited Liability Partnership

Limited Liability Partnership

University

10 Qs

Article 11 - Teaching Conditions

Article 11 - Teaching Conditions

University

15 Qs

NFPA 25 5.4 review quiz

NFPA 25 5.4 review quiz

Assessment

Quiz

Professional Development

University

Medium

Used 218+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a sprinkler has been removed for any reason, it_____ be reinstalled.
shall not
shall
should 
should not

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Replacement sprinklers_______ have the proper characteristicsfor the application intended, which include the following:(1) Style(2) Orifice size and K-factor(3) Temperature rating(4) Coating, if any(5) Deflector type (e.g., upright, pendent, sidewall)(6) Design requirements
may
might
shall
should

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Only_____ sprinklers shall be used to replace existing sprinklers
new,listed
approved
spray
special

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Special and quick-response sprinklers as defined by NFPA13, Standard for the Installation of Sprinkler Systems, _____ replaced with sprinklers of the same orifice, size, temperature range and thermal response characteristics, and K-factor.
should
shall be
may be
shall never be

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A supply______ spare sprinklers shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be promptly replaced.
of 2 to 3
of at least 5
of at least six
of at least 12

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where dry sprinklers of different lengths are installed, spare dry sprinklers____ required.
should be
should not be
shall be
shall not be

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The stock of spare sprinklers required for protected facilities having over 1000 sprinklers is no fewer than ____ sprinklers.
6
12